GSE - HANGAR 'GPU' GROUND POWER GENERATOR UNIT FMC JVT PWM - 2 GPU- USED GSE
  • FMC / JVT 90 KVA GPU MODEL PWM2
  • FMC / JVT 90 KVA GPU MODEL PWM2
  • FMC / JVT 90 KVA GPU MODEL PWM2
Vote now!
5.0/5 (2 votes)

FMC JVT JETPOWER MODEL: PWM2 400 Hz. GROUND POWER SYSTEM "GPU"

MAXIMUM INPUT CURRENT
45 KVA: 380V 63 AMPS | 400V 60 AMPS | 415V 58 AMPS | 480V 50 AMPS
90 KVA: 380V 126 AMPS | 400V 120 AMPS | 415V 116 AMPS | 480V 100 AMPS
140 KVA: 380V 196 AMPS | 400V 186 AMPS | 415V 179 AMPS | 480V 155 AMPS
180 KVA: 380V 252 AMPS | 400V 239 AMPS | 415V 232 AMPS | 480V 200 AMPS
HOUSING
Completely sealed with no air transfer from external sources to internal electronic circuits (NEMA 3R or IP23) with an Aluminum case and structuralmembers. Case is fully alodine treated. Custom colors are available.
NOISE
Not greater than 65 dBA at 1.5 m height, 1 m distance.
ENVIRONMENTAL CONDITIONS
Capable of normal operation from -40°C to +55°C (-40°F to +131°F).
IMPUT
AC Power: 380-480 Volt, 3 phase, 50/60 Hertz, at -15% to +10% of nominal voltage rating, unit is phase rotation independent.
Starting Current: Starting inrush not to exceed 100% current required when operating at rated output.
Power Factor: From 25% to 100% rated load, input power factor is greater than 0.95.
Input Current Distortion: 10% or less input current distortion from the mains with the standard 12 step rectifier system.
Efficiency: Greater than 91% at any load above 50% of rated load.
OUTPUT
Voltage Drift: Less than 1% at constant load (ambient temperature change 55°C in 8 hours).
Voltage Regulation: Better than 1%.
Total Harmonic Distortion: Less than 3% (line-to-line/line-to-neutral).
Individual harmonics less than 2%.
DC Content: Less than 100 mV.
Voltage modulation: Less than 0.5% as measured from the peak of one waveform to the peak of another adjacent waveform under steady rated load conditions.
Transient Performance: Output voltage recovery less than 50ms at 100% load change.
Voltage Operating Range: +/- 10% of rated voltage.
Output Frequency Regulation: 400 Hz +/- 0.1%.
Balanced Phase Displacement: 120° +/- 1.5° (balanced load).
Unbalanced Phase Displacement: 120° +/- 4.0° (15% unbalanced load).
EQUIPMENT INFORMATION
Equipment Type: HANGAR GROUND POWER UNIT
SPECS:

DIMENSIONS

WIDTH: 60 INCHES

HEIGHT: 24 INCHES

DEPTH: 50 INCHES

WEIGTH APPROX:

45 KVA-90KVA: = 1200 LBS.

140 KVA-180 KVA:= 2000 LBS.

 

SPECIFICATIONS:

 

Request a Quote